Color Charts
Click to see the Color Charts which can be used on all Nestavilla buildings.
NESTAVILLA DOUBLEX PRACTICAL PREFABRICATED HOUSE
TECHNICAL SPECIFICATIONS
1- GENERAL SYSTEM DESCRIPTION:
PRODUCTION TECHNOLOGY : DIN EN 10326 standard thin section galvanized C and U profiles, produced by S320GD+Z,+AZ Erdemir quality no:1332, S350GD+Z,+AZ Erdemir quality no:1335, and/or Erdemir quality no: 1322 material in Cad-Cam controlled full automatic continue roll-form machines as one-piece are used on the lifting system. Production does not involve welding.
ASSEMBLY :Wall Panels, Roof Beam, Beams and Mezzanine are assembled with Special Screws and Bolts without Welding. This allows multiple Disassembly-Assembly.
STATIC CALCULATINS :Calculations regarding compliance of the building to its purpose, and seismic and static calculations depending on the region, are made by Sap2000, CFS, STA4CAD, BRICSCAD, HAYESCAD programs in accordance with the load values defined in project and standards, as well as Turkish Standards and/or International Standards as defined in item 3.
HEAT (CLIMATE) CALCULATION : Outer Wall and Roof are detailed in consideration with the climatic conditions of the region and to comply with the Isolation Values as recommended in TS 825’de. (Heat Values maintained in Nestavilla are suitable for all regions in Turkey.) There is isolation material also between dikme C profiles of the panels. Therefore Heat Balance is not required.
ELECTRICAL INSTALLATION :Inner and Outer Wall Panels are produced as UNDERCOATING in our factory and then transferred to the assembly area. Fault Current Relay is available.
COMFORT (Optional) : Europe originated NOISE ABSORBING ceiling roof system. (~ 15 Db) and Europe originated Floating Covering offers a more comfortable building. Suspended Roof Plaster plates are complete and sutured.
AESTHETICS : For Panel connections; Pvc T profiles are used in Inner Surfaces, whereas 30 mm thick Cement Shiver Plate (Betopan) laths are used in Outer Surfaces. Outer surface coating is CE approved (Fire and Water Resistant) Decorative Shield and Sutured Cement board.
2- NESTAVILLA HOUSE SYSTEM, COMPLIANCE STANDARDS:
TS 11372 :Steel Buildings – Light – Generated by Cold Shaped Profiles– Calculation Rules
TS 648 : Calculations and Construction Rules for Steel Buildings
TS 6793 : Usage and Settlement Loads in Houses and Utilities
TS 498 : Calculation Values for Dimensioning of Construction Elements
TS 7046 : Principles for Construction Design
TS ENV 1993–1–2 :(Eurocode 3) Design of Steel Buildings Volume 1–2: General Rules- Constructional Design Against Fire
TS 4561 : Calculation Rules of Steel Buildings According to Plastic Theory
TS ENV 1090-1 : Steel Construction Applications –Volume 1:General rules and rules for buildings
TS ENV 1090-3 : Steel Construction Applications – Volume 3: Additional rules for steel resistant to High Currency.
TS ENV1998-1 :Eurocode 8: Projecting Buildings Resistant to Earthquake –Volume 1: General rules , rules for seismic effects and buildings.
TS EN 10326 : Delivery Terms for plates produced by continuous hot galvanized Construction Steel
TS EN 10327 : Delivery Terms for plates produced by continuous hot galvanized, cold shaping purpose, low Carbon Steel
TS EN 10162 : Steel Profiles – Cold rolled – Technical delivery conditions – Size and section tolerances,
TS EN 20898 : Mechanical specifications of connection elements
TS 3611EN 20898-2 : Mechanical specifications of connection elements – Volume 2: Experiment Load Values Determined Nuts—Normal Step
3- DECORATIVE – SHIELDED OUTER WALL DETAIL
Recommended Insulation Values Acc. to TS825 MAINTAINED HEAT INSULATION VALUES
1st Climate Region : 0.80 W/m2K 0.442 W/m2K (Compliant)
2nd Climate Region : 0.60 W/m2K 0.442 W/m2K (Compliant)
3rd Climate Region : 0.50 W/m2K 0.442 W/m2K (Compliant)
4th Climate Region : 0.40 W/m2K 0.398 W/m2K (Compliant)
Outer wall Thickness :100 mm (110 mm for 4th Cilmate Region)
Outer Surface Coating :12 mm thick, decorative, cemented board (Shielded and decorative sutured) (CE approved)
Heat and Noise Insulation Material: 75 mm thick Polistren Foam (Eps)(16kg/m3)
(95 mm thick for 4th Climate Region)
(Fire Strength: “B1” class “flame resistant” material in accordance with DIN 4102.
Carrier Panel Construction : Specially shaped Galvanized C Profile.
Preventing Cold Bridge For Cold Area: 10 mm water-resistant wooden lath. (20 mm for 4th Cilmate Region)
Panel Connection System : Galvanized C profile produced one-piece in Cad-Cam controlled continue roll-form machines. (70 mm) (Static calculation: 1 – 4 mm thick)
Outer Wall Inner Coating : 8 mm thick cemented board
Outer Wall Inner Coating Paint : Plastic Paint (Double Coating)
Outer Wall Outer Coating Paint : Acrylic Paint (Double Coating)
Outer Surface Accessories : 30 mm thick cemented board.
Window Accessories :30 mm thick cemented board.
4- INTERNAL WALL DETAILS
Inner Wall Thickness : 60 mm
Inner Surface Coating : 8 mm thick cemented board. (CE approved)
Heat and Noise Insulation Material : 44 mm thick Polistren Foam (16kg/m3)
(Fire Strength: “B1” class “flame resistant” material in accordance with DIN 4102.)
Carrier Panel Construction: Galvanized C profile produced one-piece in Cad-Cam controlled continue roll-form machines (44 mm) (Static calculation: 1 – 4 mm thick)
Panel Connection System : Connected by special design and detail Galvanized
connection elements, bolt and screw without welding.
Decorative Pvc T profiles in joints of the panels.
Inner Wall Inner Coating : 8 mm thick cement shiver plate (CE approved)
Inner Wall Inner Coating Paint : Plastic Paint (Double Coating)
Wet Volume Inner Coating :12,5 mm thick Water resistant Plaster Plate (Wr)
5- CEILING ROOF DETAIL (Suture Banded, hidden joints)
Ceiling Roof Coating :12,5 mm thick Fx Plaster Plate (Wr Water resistant plaster plates in wet volumes) Suture band applied in joints.
Insulation Material :80 mm thick Rolled Fiber (Water resistant due to lack of Hygroscopck and capillary property.)
6- ROOF DETAIL
Recommended Insulation Values Acc. to TS825 e SAĞLANAN ISI YALITIM DEĞERİ
1st Climate Region :0.50 W/m2K 0.440 W/m2K (Compliant)
2nd Climate Region :0.40 W/m2K 0.361 W/m2K (Compliant)
3rd Climate Region :0.30 W/m2K 0.234 W/m2K (Compliant)
4th Climate Region :0.25 W/m2K 0.234 W/m2K (Compliant)
Roof Coating Alternative–1 : Metal Based Tile Form (Metal Tile)
Roof Coating Alternative –2 : Shingle
Truss : Specially Shaped galvanized profile
Vapor Balance : HDPE touch fiber cover
Constructive Coating : 11 mm OSB-3 (Compressed fiber wooden plate)
Roof Support System : Made of specially designed galvanized sheet. Connected by bolt and screws without welding.
Insulation Material : 80 mm thick Fiber (14 kg/m3) (For 1st Climate Region)
Insulation Material :100 mm thick Fiber (14 kg/m3) (For 2nd Climate Region)
Insulation Material :160 mm thick Fiber (14 kg/m3) (For 3rd – 4th Climate Region)
Ceiling Roof construction : Specially designed Omega Profiles.
Rain Channel and Stream : Square section coat coil painted galvanized stream and drops.
Fringe Coating : 40 cm wide 12 mm thick cement shiver plate
7- DOORS
EXTERNAL DOORS:
Size :890 x 1960 mm
Door : Steel door without furnishing
Door Casing : Cylindrical lock / Metal door knob
INTERNAL DOORS:
Size :840 x1960 mm
Door :American panel ( 40mm ) White
Door Casing :Metal Door Casing (Wooden Door Casing Oprtional)
Lock / Knob : Embedded Lock / Metal door knob
Door is detailed considering 4 cm Handgrip.
8-WINDOWS
Window :90x130 cm PVC material
Housing : SPECIAL PRODUCTION BETOPAN HOUSING
Horizontal window : 60 / 40 cm PVC material
9-GLASS
Window :4+9+4mm heat control coated double glasses
Horizontal window :4mm thick frosted glass
10-MEZZANINE SYSTEM
Standard Mezzanines;
Carcass : Formed by combination of special flect profile cage panels with special Nestavilla details. Parts like outer walls, inner walls, beams in Nestavilla are made of galvanized special flect profiles, and production and assembly do not involve welding.
Upper Coating :16 mm Betopan (cement shiver plate) (CE Approved)
Ceiling Roof Profile :15 Db Noise Absorbing Protector Ceiling Roof Profile and Clips (Europe originated)
Ceiling Roof :12,5mm thick White ALCIPAN
Insulation :80 mm thick Mattress Fiber ( 14 kg/m3 )
Load : Taking usage purpose of the building into consideration, mobile load
value is assumed in accordance with TS 498. (200–350-500 kg/m2)
Note : Upon request, (Optional) Europe originated –Stroke absorbing –Nestavilla Comfort Mezzanine Floor’ng System is used.
11-STAIRS
Carcass : Carcass made of galvanized steel profiles.
Stair Coating : Colored Polished Beech Coating
Railing : Profile system railing.
Note: Wooden ladder and railing are optional.
12-PAINT
Outer Surface :2 coats Acrylic outer surface paint
Inner Surface :2 coats Plastic paint (colors shall be determined by the contractor.)
Ceiling :2 coats Plastic paint (colors shall be determined by the contractor.)
Note: Textile based Decorative Wallpaper is used instead of Inner Surface Paint upon your request.
13-ELECTRICAL INSTALLATION (UNDERCOAT)
Cable 250 V
Sockets, Switches Günsan made – Başak series
Socket Cables NYM and NYA 3x2,5 mm2 (Özgüven – Öznur)
Illumination Cables NYM and NYA 2x1,5 mm2 (Özgüven – Öznur)
Illumination Armatures Normal spaces 2x40 FLUORESCENT
Wet spaces Round Globe– Diamond-Shaped
Outer Door Top Outer Globe – Diamond-Shaped
Fuse, fuse boxes Federal– Cetsan – Diamond-Shaped
Electrical Board Contractor’s responsibility.
Telephone Installation Contractor’s responsibility.
Main Line Connection Contractor’s responsibility.
Illegal Currency Relay : Illegal Currency Relay available in all buildings.
NOTE: Stove, Air Conditioner, Electrical Radiator usage should be specified in the project.
Each heater, air conditioner shall be fed by a separate fuse line.
14-SANITARY INSTALLATION (OVERCOAT)
Pipes (potable water PPRC pipe (Fırat Made)
Pipes (drain) PVC pipe ( Fırat Made)
Fittings and Armatures:
Sinks 40x50cm Whole Stand (AYVİT-ALVİT)
Sink Tap Taps Sink Outrun. (İNCİ-GÜNEL)
Closet Ceramic reservoir (AYVİT-ALVİT)
Shower Basin 80*80 Marmoreal
Shower battery Mix bath battery
Lustration Tap Taps mounted on the wall. (TSE Approved)
Kitchen Installation Hot/Cold water installment, No cabinets in the kitchen.
Main line connection Contractor shall be responsible for drain and potable water main lines and connections.
Not : Installations are tested in our facilities prior to delivery.
15-PACKAGING FOR DOMESTIC TRANSPORT (Optional):
Packaging can be arranged depending on the transportation type (Land, Sea, Air). Please contact our Logistics Department for detailed information.
16-OTHER
Please contact our Sales Representative for Various Wall Thickness alternatives, our references, and additional information.
|